georgia-market.com moderated newsgroup and market bazzar   >   LaGrange   >   Construction   >   Hioki 8421-51 memory datalogger 16 channels - hti

Hioki 8421-51 memory datalogger 16 channels - hti


"Your One Stop Source for Sales & Calibration of Test & Measurement Equipiment"
*Hioki 8421-51 Memory Datalogger 16 Channels - HTI *
All analog inputs fully isolated!
Voltage/temperature loggers with PC networking support
8420-51(8ch), 8421-51(16ch), 8422-51(32ch) All analog channels isolated.
Temperature, voltage, humidity, cumulative pulses, rotations
Max. 32-channel, 100ms high-speed multi-channel data collection
Simultaneous numerical and graphical display
Attachable Printer and I/O Module
Up to 16 HiLOGGERs can be connected and controlled via LAN.
Temperature, voltage, humidity (with optional sensor), cumulative pulses, rotations
Input channels Analog 8 channels isolated PHOTO-MOS relays
Pulse Inputs: 4 ch, Logic Inputs: 16 ch (using the 8993 DIGITAL I/O UNIT)
Thermocouple types K, E, J, T, N, W (WRe5-26), R, S, and B
Platinum measurement resistance types Pt 100, JPt 100, 3- and 4-line types
Analog voltage input 4 ranges: 100 mV, 1 V, 10 V, 100 V and 1-5 V f.s.
Recording interval 100 ms to 1 hour (5 s to 1 hour when measuringhumidity). Note: All input channels are scanned at high speed during each recording interval.
Digital Filter OFF/50Hz/60Hz (when set to 50 or 60Hz), the appropriate digital filter is automatically set according to the recording interval
Memory capacity Internal: 32 MB (16MW data points), External:up to 1G (9726/ 9727/ 9728/ 9729 PC card, 128MB to 1GB)
Real-Time save Waveforms are saved as binary data to the PC Card in real time. Stored data can be recalled by the instrument in blocks of 32 MB each.
PC interface RS-232C and 10Base-T Ethernet connectors
(optional, sold separately) 8992 PRINTER UNIT (Detachable type) or 8993 DIGITAL I/O UNIT (Detachable type) can be connected
Recording and display 5.7-inch STN color LCD, 112 mm (4.4 in) × 18 m (59.06 ft), thermal paper roll
Power supply (1) AC ADAPTER 9418-15 (12 V DC ±5 %), (2) BATTERY PACK 9447 (NiMH, when used with AC adapter, the adapter has priority), (3) 12V car battery (using connection cable – please inquire)
Dimensions, mass 234 mm(9.21 in)W × 170 mm(6.69 in)H × 52 mm(2.05 in)D, 1.4 kg (49.39 oz) (instrument only, without battery)
310 mm(12.20 in)W × 170 mm(6.69 in)H × 52 mm(2.05 in)D, 1.7 kg (59.98 oz) (with printer, without battery)
302 mm(11.89 in)W × 170 mm(6.69 in)H × 52 mm(2.05 in)D, 1.7 kg (59.98 oz) (with Digital I/O Unit, without battery)
Accessories AC ADAPTER 9418-15 (1), Terminal Cover (1), Screwdriver (1), Wave viewer software (1), Interface Manual FD (1)
GOODS: ALL our items are FACTORY NEW



Hioki 8421-51 memory datalogger 16 channels - hti