THIS IS A NEW RANCO C12-9018 36 IN CAPILLARY BULB THERMOSTAT. 20A 240/277 VAC. 1/4 INCH MALE SPADE LUG. TERM 1 = NC TERM 2= COM TERM3=NO
ROBERT SHAW AND OTHERS USE SAME # WITH ONLY BRAND CHANGE. THIS UNIT IS VERY VERSATILE REPLACING HUNDREDS OF SHORTER CAPILLARY UNITS. WARNING DO NOT KINK OR CRIMP CAPILLARY IT WILL NOT FUNCTION PROPERLY. CAN BE USED WITH A RELAY TO ACHIEVE MULTIPLE POLE OPTIONS AND OTHER EQUAL SWITCHES.
SHORT LIST FROM ONE CATALOG: ROOM AIR CONDITIONER CONTROLS C12/C21SINGLE STAGE CONTROL These controls replace many OEM controls on single stage packaged terminal, room, and thru-the-wall heat/cool units.
ELECTRICAL RATING RATING 125V 240V 277V FULL LOAD AMPS 20 20 16 LOCKED ROTOR AMPS 80 80 60
PILOT DUTY (VA) 240 240 240 RESISTIVE LOADS AMPS 25 – 16
ORDER NO. SWITCH RANGE (°F) DIFFERENTIAL (°F) SENSING ELEMENT REPLACES
C12-5010 60 TO 98 36” CAPILLARY WITH 3/8 X 9” BULB
C12-9025 SPDT 60 TO 93 3 YORK #026-17371-00
C12-9018 60 TO 89 SIGNER/MCQUAY 02005451
C21-2014 54 TO 90 4 21” CAPILLARY WITH 31/64” X 5-1/2” BULB G.E. 21B20162-P04
THIS IS A BRAND NEW THERMOSTAT WITH THE RATINGS AND CROSS REFS SHOWN BELOW. IT REPLACES MANY AC AND OTHER ROOM TEMP CONTROLS. IT CAN BE USED IN ELECTRIC HEATER CIRCUITS OR AS A LOW VOLTAGE CONTROL... ANY USE YOUR IMAGINATION CAN COME UP WITH.
THE BEST THAT WE HAVE SEEN DONE IS IN EVAPORATIVE COOLERS. WE MOUNT THIS IN THE UNITS AIR FLOW AND AT NIGHT TIME IT SHUTS DOWN THE FAN WHEN THE TEMPS DROP TOO COOL. IT LEAVES THE PUMP GOING SO THE COOLER WILL START UP COLD AS THE DAY WARMS... SO WHAT CAN YOU USE THIS FOR???
CONTACT US IF YOU NEED MORE THAN ONE FOR REDUCED PRICES!!
OUR MOTTO: YOU WAIT ON THE MAILMAN NOT US!
Cross References: Our book shows these as equals but please check for yourself!
WE WILL NOT BE RESPONSIBLE FOR WRONG CROSS REFERENCES! BASICALLY THE DIFFERENCES ARE SLIGHT TEMPERATURE VARIATIONS IN LIMITS AND DIFFERENTIALS.
Ranco 5010 60 to 98 F Room Air Conditioner Thermostat.( 3/8” X 9” Bulb)
RANCO HTG/CLG A/C CON (Ref# 621960)
Single Stage Control For Packaged Terminal,
Room and Through-The-Wall Heat/Cool Units
This control replaces many OEM controls on heat/cool units. C12-9025 replaces
York 026-17371-00 / Heil Quaker 40889-001. C12-9018 replaces Singer /
McQuay / Snyder General 02005451 and 02005610.
60 to 98 3/4” 36” Cap. with 3/8 x 9” Bulb
Ranco Type C12 Thermostat The C12-5010 Cross Ambient Thermostat will perform one of two functions – Cooling Only or Heating Only. (For Heating-Cooling operation, a manual selector switch is necessary for heat pump applications since the C12 alone will not automatically perform this function). The switch is basically an SPDT snap-acting type. Normally closed contacts open on a drop in temperature. Field adjustment is not recommended on the Range and Differential screws. However, there is a dial adjustment for a wide temperature range. The bulb of the liquid filled element is the controlling point regardless of the temperature at the bellows and capillary tubing. Ambient temperatures have an effect on the switch operation of the C12 control. A temperature of 27°C is the selected ambient point used by the factory on control calibration. A change in ambient temperatures above or below 27°C will shift the setting slightly lower or higher respectively.
066-A-301 HEAT EXCHANGERS INC.
1741226 CHRYSLER/AIRTEMP 1742095 1742420 1747512 2019451 2776644 2776646 3524006
20-3784 NORGE 20-4651 20-6082 21-0773 21-2572 21-2573 21-2578
24254200 FREIDRICH GRP-WYLAN 24309800 FREIDRICH GRP-WYLAN
(***)-102-0011 EXPORT (***)-102-0012 EXPORT
294076 WESTINGHOUSE 350A021H02 350A052H02
4EKB-1967A AMERICAN AIR FILTER 4EKB-2700 4ELN-2700C 4ELN-2700D 4ELN-2700F 4ELN-3033 4ELN-7977 13211E4621
588C966H02 WESTINGHOUSE 595C966H01 595C966H02
613-433-00 FREIDRICH GRP-WYLAN
6541357 FRIGIDAIRE 6544624 FRIGIDAIRE 6572402 FRIGIDAIRE 6572700 FRIGIDAIRE 6572792 FRIGIDAIRE
84303-5 KRACK CORP. 84303-6 KRACK CORP.
934B963 GE/HOTPOINT 935B963P02 GE/HOTPOINT
9997-051 UNI-LINE 9997-384 UNI-LINE 92088 UNI-LINE
B110538 BIRTMAN ELECTRIC CO. B110559 BIRTMAN ELECTRIC CO.
C12-2011 ALL FOLLOWING ARE RANCO # C12-2015 C12-2016 C12-2029 C12-5010-35 C12-5010-57 C12-5010-70
C12-5015 C12-5019 C12-5020 C12-5021 C12-5022 C12-5024 C12-5025 C12-5026 C12-5027
C12-5029 C12-5034 C12-5035 C12-5036 C12-5037 C12-5038 C12-5039 C12-5041 C12-5044 C12-5048 C12-5050 C12-5051 C12-5053 C12-5055 C12-5056 C12-5058 C12-5062 C12-5065 C12-5070 C12-5078 C12-5086 C12-5087 C12-5092 C12-5110 C12-5111 C12-5114 C12-5116 C12-5119 C12-5119-57 C12-5120 C12-5128 C12-5129 C12-5135 C12-5137 C12-5144 C12-5010 C12-5147
C12-5148 C12-5153 C12-5154 C12-5157 C12-5158 C12-5161 C12-5163 C12-5166 C12-5168 C12-5172 C12-5179 C12-5180 C12-5185 C12-5186 C12-5192 C12-5194 C12-5196 C12-5197 C12-5199 C12-5200 C12-5204 C12-5207 C12-5207-57 G2-5781 RANCO
C12-5211 C12-5212 C12-5213 C12-5215 C12-5217 C12-5218 C12-5225 C12-5228 C12-5231 C12-5233 C12-5234 C12-5235 C12-5245 C12-5247 C12-5254 C12-5254-57
C12-5259 C12-5259-57 C12-5262 C12-5267 C12-5279 C12-5284-57 C12-5291-57 C12-5505 C12-5507 C12-5514 C12-5516 C12-5781 C12-9001 C12-9002 C12-9003 C12-9005 C12-9006 C12-9009 C12-9027 C12-9033 C21-2010
C12-5010 C293977 WESTINGHOUSE C293985 C294075 C294076 C295430 C295431
E12491 QUIET KOOL (EMERSON) E-12491 EMERSON E12531 QUIET KOOL (EMERSON)
HH22UB052 CARRIER/AIR COND.CO.
O25-12210-00 BORG-WARNER (YORK) O25-12550-000 BORG-WARNER (YORK) O25-16272-000 BORG-WARNER (YORK)
P1013-0002 COMMAND-AIRE P1078-0001 COMMAND-AIRE
P-8-7183 LENNOX INDUSTRIES P-8-7193 LENNOX INDUSTRIES P-8-9041 LENNOX INDUSTRIES
WJ28X32 GE/HOTPOINT WJ28X44 GE/HOTPOINT WJ28X70 GE/HOTPOINT
These controls replace many OEM controls on single stage packaged terminal,
room, and thru-the-wall heat/cool units.
ORDER NO. SWITCH RANGE (°F) DIFFERENTIAL (°F) SENSING ELEMENT REPLACES
C12-5010 60 TO 98 36” CAPILLARY WITH 3/8 X 9” BULB
C12-9025 SPDT 60 TO 93 3 YORK #026-17371-00
C12-9018 60 TO 89 SIGNER/MCQUAY 02005451
C21-2014 54 TO 90 4 21” CAPILLARY WITH 31/64” X 5-1/2” BULB G.E. 21B20162-P04