georgia-market.com moderated newsgroup and market bazzar   >   Gainesville   >   Construction goods   >   Kenwood cs-5400 100 mhz oscilloscope

Kenwood cs-5400 100 mhz oscilloscope


"Your One Stop Source for Sales & Calibration of Test & Measurement Equipiment"
* Kenwood CS-5400 100 MHz Oscilloscope*
The CS-5400 Series are 3-channel oscilloscopes developed with concepts of high level design, high accuracy and easy operation. The panel layout never diminishes the intuitive and high-speed response provide fatigue free operation even after long-hours of use. These models incorporating readout function (with CS-5400 / 5450) offer you parameter measurement and auto setup functions enabling to measure AC voltage (Vp-p), DC voltage, frequency and period. All of these models are provided with full features including 2% high-accuracy measurement, delay sweep function, automatic triggering and high intensity, high-resolution CRT. The CS-5400 Series with high-performance will surely assist you in many kinds of field activities.
* V Mode Sync for Stable Display of 3 Signals
* Maximum Sweep Rate of 5 ns/div (x10 MAG)
* Variable Hold-off Allowing Observation of Waveforms with Complicated Cycle
* Wide Dynamic Range and Distortion-Free Accurate Waveform Display
* 3-Channel 8-Trace Waveform Display
* Built in Video Clamp Circuit for Easy Operation
* Peak to Peak Voltage Measurement(CS-5400/5450)
* High-Accuracy ¤ 2% Design for More Precision Measurement
* Single Sweep for Observations of Single-shot Channel
* Automaticv Sync (FIX) Function
* Delayed Sweep with Waveform Partial Magnification Capability
* CH1 Signal Output Connector
* Cursor Measurement Function(CS-5400/5450)
* Easy Operation Panel Layout
* Parameter Auto Measurement Function
* High-Accuracy Calibration Signals
* High-Sensitivity Design with Vertical Axis of 1 mV/div
* Variable Lock(CS-5400/5450)
* Auto Setup Function(CS-5400/5450)
* Square-Type 150 mm CRT with Self-Illuminated Light and Inside Scale (12 kV)
150mm rectangular with internal graticule 8 x 10 div. (1 div.=10mm)/approx 12kV
Vertical axis sensitivity 5 mV to 5 V/div
Vertical axis sensitivity 1mV, 2mV/div
1-2-5 steps, 12 ranges, and fine adjustment within the selected range
Vertical axis frequency response 5mV to 5 V/div.
DC:DC to 100 MHz (within-3dB); AC: 5 Hz to 100 MHz (within-3 dB)
Vertical axis frequency response 1mV, 2mV/div.
DC:DC to 20 MHz (within -3dB); AC: 5 Hz to 20 MHz (within -3 dB)
Vertical axis rising time 5mV to 5V/div.
Vertical axis rising time 1mV, 2mV/div.
Vertical axis signal delay time
Leading edge can be confirmed using a square wave that has a rising time of less than this unit
Vertical axis max. input voltage
800 Vp-p or 400 V (DC AC peak, 1khZ)
Vertical axis frequency response
Vertical axis signal delay time
Leading edge can be confirmed using a square wave that has a rising time of less than this unit
Vertical axis max. input voltage
100 Vp-p or 50 V (DC AC peak, 1 kHz)
Vertical axis chopping frequency
Vertical axis polarity inversion
Horizontal (CH2 input, except x 10 MAG) sensitivity 5mV to 5V/div.
Horizontal (CH2 input, except x 10 MAG) sensitivity 1mV, 2mV/div.
Horizontal frequency response DC
Horizontal frequency response AC
Horizontal X-Y phase difference
Less than 3 degrees at 100 kHz
Switchable to X-Y mode with H.MODE key CH1:Y axis, CH2: X axis
0.5 s to 50 ns/div. +2%, 1-2-5 step, 22 ranges, fine adjustable within the selected range.
50 ms to 50 ns/div + 2%. 1-2-5 step, 19 ranges
x 10 +5%, (+8% at 0.5 us/div.)
A Sweep, continuously variable +4 div. with respect to A sweep
B Sweep is a continuously varible +4 div. with respect to A sweep.
Continuous delay (After Delay), Synchroonous delay (B TRIG'D): Synchronized with trigger signal
Sweep delay sweep mode B TRG'D
Synchronous delay (B TRIG'D): SYNCHRONIZED with trigger signal
Continuously variable from 0.2 div. to 10 div. (0.5s/div. to 50ns/div.)
+(3% of setting value 1% of full scale) (0 to 300 ns)
20000 (10 times of A Sweep setting value) :1 (at A Sweep 1 ms/div, B Sweep 1 us/div.)
AUTO, NORM, FIX, SINGLE, RESET
Triggering mode trigger sources
Triggering mode trigger coupling
Triggering coupling AC-frequency-NORM-FIX
10Hz to 50MHz; 1.0 div.; 1.5div.; 50MHz to 100MHz; 1.5 div; 2.0 div.
Triggering mode coupling HF-REJ-frequency-NORM-FIX
10Hz to 10Hz; 1.0 div; 1.5 div; 10 kHz or more; >min; >min
Trigger sensitivity DC coupling, frequency, NORM, FIX
Trigger sensitivity DC coupling, frequency, NORM, FIX
50MHz to 100MHz, 1.5 div, 2.0 div
Trigger sensitivity TV-F, TV-L, coupling, frequency, NORM, FIX
Composite video signal, 1.5 div
Intensity modulation input voltage
Intensity modulation input impedance
Intensity modulation frequency response
Intensity response max. input voltage
84 Vp-p or 42 V (DC AC peak, 1 kHz)
CH1 signal output (50W load) output voltage
CH1 signal output (50W load) output impedance
CH1 signal output frequency response 5 mV to 5 V/div.
1 mV, 2 mV/div., 100 Hz t 20 MHz (-3dB)
CH1 signal output trace rotation
Enables trace rotation adjustment by semi-fixed controller on the panel
Power requirements input voltage
Power requirements power consumption
Power requirements insulator voltage
Power requirements insulator resistance
Dimensions/Weight dimensions(WxHxD)
305x150x400mm/(344x165x459mm, Maximum dimensions)
Operating Environment (limited as indoor use) altitude
Operating environment overvoltage category
Operating environment pollution
Operating environment operating temperature & humidity
0 to 40 degree, 85% or less (with no condensation)
Operating environment storage temperature & humidity
-20 to 70 degree, 85% or less (with no condensation)
PC-51(2); operation manual (1) Adjusting Scewdriver (1) Power Cable(1) Replacement(1)
Readout section panel setup value
CH1, CH2 scale factor (with probe detection), CH3 scale factor, V-UNCAL, ADD, INV, A/B Sweep scale factor (MAG conversion, "*" is displayed in MAG mode), X-Y, Sweep UNCAL, DELAY, TIME, B TRIG'D
Cursor measurement V1 only in X-Y mode (measures between DREF and cursor except the parameter automatic measurement)
V1: Voltage display by converting CH1 scale factor; V2:Voltage display by converting CH2 scale factor;V3:Voltage display by converting CH3 (0.1V/div. or 0.5V/div.) scale factor; T: Time display by converting A Sweep scale factor ; 1/T: frequency display b
GOODS: ALL our items are FACTORY NEW



Kenwood cs-5400 100 mhz oscilloscope