georgia-market.com moderated newsgroup and market bazzar   >   Brunswick   >   Industrial   >   Heavy Industrial   >   ICM1503 oil burner control 45 second replaces R8184G

ICM1503 oil burner control 45 second replaces R8184G


• Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
• Solid state flame sensing circuit
• LED on terminal strip indicates system lockout
• Enclosed safety switch with external reset button
• Mounts on standard 4 x 4 in. junction box; select models may be mounted directly on burner housing
• C554A Cadmium Sulfide Flame Detector and 24 VAC thermostat required
• Direct replacement for popular competitive models. Ignition Type Intermittent: Timing, Safety Switch • 45 seconds.
Mounting Bracket • For mounting on a standard 4” X 4” junction box or direct mounting on burner housing
Electrical Rating; Contacts (full load) • 7.4 A @ 120 VAC; 3.7 A @ 240 VAC Electrical Rating; Contacts (locked rotor) • 44.4 A @ 120 VAC; 22.2 A @ 240 VAC
Dimensions •4 3/8 in. high x 4 1/8 in. wide x 2 1/2 in. deep • 111 mm high x 104mm wide x 64mm deep.
Temperature Range • -30°F to +130°F.
Approvals • Underwriters Laboratories Inc.
REPLACES- CARLIN: 48245, HONEYWELL: R8184G4009, R8184G1138, R8184G1427, R8184G4025, TEMPSTAR/HEIL: 1147017, WHITE RODGERS: 668-401. (SAFTEY TIMING 45 SECONDS).ICM ICM1503



ICM1503 oil burner control 45 second replaces R8184G